The Chamberlain Group, Inc.845 Larch AvenueElmhurst, Illinois 60126-1196www.liftmaster.com Please read this manual and the enclosed safety materials
10HARDWAREAttach the Cable Tension Monitor (Required)123454NOTE: The cable tension monitor is shipped for left side installation. It is recommended th
11Locate door control within sight of door, at a minimum height of 5 feet (1.5 m) where small children cannot reach, away from moving parts of door an
12The remote light (garage door opener light) is designed to plug directly into a standard 120V outlet. Select an appropriate location on the ceiling
13Electrical Requirements7InstallationPERMANENT WIRING CONNECTIONIf permanent wiring is required by your local code, refer to the following procedure.
14If the optional EverCharge® Standby Power System is part of this installation it should be installed at this time. The SPS can be mounted to either
15The safety reversing sensor must be connected and aligned correctly before the garage door opener will move in the down direction. This is a require
16Floor Installation1. Use wood blocks or extension brackets (see Accessories) to elevate sensor brackets so the lenses will be no higher than 6&quo
17InstallationRun the wires from both safety reversing sensors to the opener. Use insulated staples to secure wire to wall and ceiling. Strip 7/16&quo
18Receiving SensorGreen LEDSending SensorAmber LEDInstallationTROUBLESHOOTING THE SAFETY REVERSING SENSORSIf the sending eye indicator light does not
19Adjust the position of the door by using the black and purple buttons. Black moves the door UP (open) and purple moves the door DOWN (close). SETTIN
2Table of ContentsINTRODUCTION 2-5Safety Symbol and Signal Word Review .. 2Planning ... 3Preparing You
20The force setting measures the amount of force required to open and close the door.Push the purple button twice to enter into the Force Adjustment M
21TESTWith the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4 laid fl at) on the fl oor, centered under the garage door. Operate the door
22If your cable tension monitor has been activated the LED on the garage door opener will blink 9 times.1. With the door fully closed, the power doo
23OperationIMPORTANT SAFETY INSTRUCTIONSTo reduce the risk of SEVERE INJURY or DEATH:WARNING WARNING WARNING WARNING 1. READ AND FOLLOW ALL WARNINGS
24(LANG) Language FeaturePress this side button to toggle between the three languages - English, French and Spanish.Degrees F/C Feature Press this sid
25OperationTo prevent possible SERIOUS INJURY or DEATH:• NEVER allow small children near batteries.• If battery is swallowed, immediately notify d
26OperationMAINTENANCE SCHEDULEOnce a Month• Manually operate door. If it is unbalanced or binding, call a trained door systems technician.• Check t
27OperationTroubleshooting (Continued)The door opens but won't close:• Check cable tension monitor (see Installation Step 4).• If the garage
28MESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMESSAGEMeaning: This message will appear if the safety reversing sensor
29Your garage door opener is programmed with self-diagnostic capabilities. The diagnostic LED will fl ash a number of times, then pause, signifying it
3PlanningabcdefSurvey your garage area to see if any of the conditions below apply to your installation. Depending on your requirements, additional ma
30ProgrammingTo Add or Reprogram a Hand-held Remote Control (Model 895MAX)To deactivate any unwanted remote, fi rst erase all codes:Press and hold the
31NOTE: Your new Keyless Entry must be programmed to operate your garage door opener.One Button Close: The garage door opener can be closed by pressin
32ProgrammingReprogramming Light or Additional LightPress and the “learn” button on the light until the LED comes ON. Activate the garage door opener
33Repair PartsInstallation Parts11N O TICE 1121314LOCK LIGH T 3245678910KEY PART NO. NO. DESCRIPTION1 398LM Smart Control Panel®2 895MAX 3-Button
34Repair PartsGarage Door Garage Door Opener Assembly Parts326541KEY PART NO. NO. DESCRIPTION1 41DJ001 Logic board complete with plate2 41A6408 Tra
35AccessoriesCLOSED OPEN 370LM373LM41A5281377LMExtension Brackets:(Optional) For safety reversing sensor installation onto the wall or fl oor.Keyless E
© 2012, The Chamberlain Group, Inc.114A3489I All Rights ReservedLIFTMASTER® SERVICE IS ON CALLOUR LARGE SERVICE ORGANIZATION SPANS AMERICAINSTALLAT
4IntroductionPreparing Your Garage DoorBEFORE YOU BEGIN:• Disable locks.• Remove any ropes connected to the garage door.Complete the following test
5Carton InventoryIntroductionSmart Control Panel®Remote Control Visor Clip3-Button Remote Control Model 895MAX (1) Remote Light(Garage Door Opener Lig
6To avoid installation diffi culties, do not run the garage door garage door opener until instructed to do so. The garage door opener can be installed
7InstallationIMPORTANT INSTALLATION INSTRUCTIONSTo reduce the risk of SEVERE INJURY or DEATH:WARNING WARNING WARNING WARNING 1. READ AND FOLLOW AL
8InstallationHARDWARE1Position and Mount the Garage Door Opener234567891NOTE: For additional mounting options refer to the accessories page.Close the
9Attach the Emergency Release Rope and HandleInstall Power Door Lock1122345623Thread one end of the rope through the hole in the top of the red handle