QuickstartEL25 Keypad Programming GuideEL25 Keypad Programming GuideTelephone entry/access control system with a 25 directory code capacity®™© 2005 Th
Page 9Programming Multiple Units OverviewNote: You cannot program a unit within a multi-unit chain from a local/remote DTMF phone (Touch-Tone) unless
Page 10Getting StartedEL25 SetUp “Your Settings”Change the unit password to prevent any tampering with your system's database. When changing the
Page 11A relay is a device that reacts to an electric current to activate other devices. Allowing the EL25 to lock or unlock a door/gate, shunt (bypas
Page 12To perform these 4 steps you MUST know EXACTLY where the External Access Control Device(s) were wired in “Your” EL25! When the table on page 14
Page 131 Press2 Enter the Relay Number (1-4). Then (#)3 Enter Activation Time (1-300 Seconds). Then (#)Then1 Press2 Enter Door Number (1-4). Then
Page 14Sample: EL25 Controlling 1 Door (Page 16)EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”When “Your Door Settings” or “Door 1,2,3 or 4” are
Page 15How your system has been wired is an important part of programming it. Write down your configuration. To help visualize it, draw a map of it be
Page 16EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”Relay 1 - Strike Mode Unlocks Door for 10 sec.Relay 2 - Control Mode Turns on Security Ligh
Page 17EL25 SetUp “Your Settings”EL25 SetUp “Your Settings”EL25Main Keypad (Front Door)Wiegand Keypad (Exit)Card Reader(Back Door)Card Reader(Manager&
Page 18Location Door No. Relay Relay Mode Relay Function Relay Activation Time (Seconds)DrivewayPedestrian GateIn EL251 Strike Opens Vehicular Gate 10
Page 1ProgrammingNumberFactorySettingDescription of Task Programming Procedure***12 # Enable/Disable True Anti-Passback (0 = disable;1 = enable) # Ena
Page 19Location Relay Relay Mode Relay Function Relay Activation Time (Seconds)Front Door (Entrance)Vehicular GatePool GateFront Door (Entrance)1 Stri
Page 20Entry CodesAccess Cards1 Press2 Enter Entry Code (3-9 digits). Then (#)Factory Setting for Entry Code Length is 4 digitsSee “Entry Code Lengt
Page 21Transmitters1 Press2 Enter Transmitter Number (1-65534). Then (#)Add a Basic transmitter to the system's database. A basic transmitter w
Page 22AppendixAppendixQuick Reference GuideGlossaryAppendixGlossaryGlossaryGlossaryGlossaryGlossaryGlossaryAccess Device (RF Receiver, Card Reader, o
Page 23AppendixAppendixQuick Reference GuideGlossaryAppendixGate or Door - Used synonymously throughout the manual, these terms refer to controllable
Page 24AppendixAppendixAppendixAppendixAccess CardsDirect CommandsEntry CodesProgramming – Enter Program Mode – Exit Program Mode – Multiple Units –
© 2005 The Chamberlain Group, Inc.All Rights Reserved114A3042845 Larch AvenueElmhurst, Illinois 60125-1196®™
Page 2ProgrammingNumber3030 # (time zone number, 2-63) # (segment number; 99) # (starting time = hhmm; 99) # (ending time = hhmm) # (day of week, 1-8;
Page 3FactorySettingDescription of Task Programming ProcedureProgrammingNumber61 # (door 1-4) # (relays to activate 0000-1111) # Order of relay is: re
Page 4FactorySettingDescription of Task Programming ProcedureProgrammingNumber86Verify a Card85Replace a Card88Delete a Card90Add a Basic Transmitter9
Page 5FactorySettingDescription of Task Programming ProcedureProgrammingNumberVerify Multi-Unit Number111 #105Enable or Disable Anti-PassbackForgivene
Page 6Programming BasicsProgramming Single Unit OverviewProgramming Single Unit Overview1 1, 2 or 3 digit Programming Number. (See “Quick Refer
Page 7Enter Programming ModeExit Programming Mode1 Press2 Enter the (6) six-digit password. The default is six zeroes.If you will be programming the
Page 8System Feedback / Responses (Beeps)2 Short Beeps: Programming step was valid.3 Short Beeps: Programming mode was exited.1 Long Beep: Input was